Banner 7 Frequently Asked Questions (FAQ)
Purpose
This document gives a brief overview of common issues
encountered when connecting and accessing Banner 7. For full details on the
differences between Banner 6 and 7 or on how to navigate Banner 7, please sign
up for Banner 7 Navigation Training. A current schedule can be found at
http://www.alaska.edu/oit/training/.
FAQ
NOTE: The fully supported web browses are Internet Explorer
5.5 SP2 and 6 on Windows and Internet Explorer 5.2 on Mac OS. Other browsers
may work, but if the browser has a problem, and Internet Explorer does not,
then the solution is to use Internet Explorer. If Customer needs to have Windows
or Internet Explorer, they need to contact their local IT support agency.
As of October 19, 2006, Internet Explorer 7 is NOT supported.
Questions
Connecting to Banner 7
-
How do I access Banner 7?
-
When logging in, do I have to enter in a Database?
-
Customer attempts to connect to Banner 7 and never gets a response or receives various error messages of items not available, etc.
-
The browser fails to properly display the Oracle Forms
or Customer gets an error reporting the wrong version of JInitiator is
installed.
-
The correct version of JInitiator is installed but
Customer continues to get either various error messages or forms do not display
properly.
-
Customer has downloaded and installed the current
version of JInitiator but keeps getting a message to upgrade JInitiator
version.
-
Customer has the current version of JInitiator
installed and cannot get the login display to access Banner 7.
-
Customer gets a Microsoft Visual C++ Runtime or Debug
error or Oracle Class Foundation Error Java Class Main Engine Not Found error.
Logging into Banner 7
-
Customer attempts to login to Banner and receives the
error message 'ORA-12560: TNS: Protocol Adaptor Error.'
-
Customer attempts to login to Banner and receives the
error message '*ERROR* Invalid version of GUAINIT.' After Customer clicks OK
they receive another error message 'FRM-40735: ON-ROLLBACK trigger raised
unhandled exception ORA-04067.'
Navigating/Using Banner 7
-
Drop-down menus fail to function correctly.
-
Customer is unable to see all the contents of the window
with the window maximized, requiring them to scroll up, down, left, and right
when using most forms.
-
The F1 key does not work.
-
Customer closed a grey Internet Explorer window and
they were immediately logged out of Banner.
-
Customer ran an Oracle Report from GJAPCTL and got a
blank screen.
-
Customer ran an Oracle Report from GJAPCTL and got an
error, "REP-56055: Exceed max connections allowed: 20." or "REP-56055: Exceed
max connections allowed: 40."
-
Customer opens a form in Banner 7 and nothing happens
except a blue cursor that moves back and forth on the lower right corner of the
Banner form.
-
Customer using a Mac reports that it is difficult to
read the text in Banner 7, and that some of the text is cut off.
-
Customer is unable to access the Banner Bookshelf.
-
What are 'My Links'?
-
What are 'Banner Broadcast Messages'?
Answers
Connecting to Banner 7
-
How do I access Banner 7?
-
In Internet Explorer, enter the generic URL for Banner 7.
Banner 7 Production - https://banner.alaska.edu
Banner 7 Training - https://ban7trnx.alaska.edu
Banner 7 PREP - https://ban7prep.alaska.edu
Banner 7 LRGP - https://ban7lrgp.alaska.edu
Back to Top
-
When logging in, do I have to enter in a Database?
-
It is required to enter the database name when logging
in. In Banner 6, this was not required for PROD and TRNX.
Banner 7 Production - PROD
Banner 7 Training - TRNX
Banner 7 PREP - PREP
Banner 7 LRGP – LRGP
Back to Top
-
Customer attempts to connect to Banner 7 and never gets a response or
receives various error messages of items not available, etc.
-
Customer has popup blockers enabled. These need to be disabled
or the Banner website added as an allowed site in the popup blocker's settings.
See Internet
Explorer – Modifying the Popup Blocker for Banner 7
-
Customer may not be an administrator of the computer and
JInitiator needs to be installed. Customer will not be prompted to install the
JInitiator if they do not have administrator access. If Customer does not have
Administrator privileges, they need to contact their local IT support agency.
Back to Top
-
The
browser fails to properly display the Oracle Forms or Customer gets an error
reporting the wrong version of JInitiator is installed.
-
Customer needs to have Administrator privileges on computer and
should remove the current version of JInitiator using Add or Remove Programs
and then try the web page again to reinstall JInitiator. The installer should automatically
download and install from the server. If Customer does not have Administrator
privileges, they need to contact their local IT support agency.
See Uninstalling
Oracle JInitiator on Windows XP
See Installing
Oracle JInitiator for Banner 7
Back to Top
-
The correct version of JInitiator is installed but Customer continues
to get either various error messages or forms do not display properly.
-
Customer can first try to delete the JAR cache and web cache and
cookie files. If this doesn't work then most likely Customer has spyware on
the computer and needs to have a spyware eradication program installed and run
on computer. Contact the local IT support agency for recommended spyware
removal tools.
See Deleting
JAR and cache/cookie files
Back to Top
-
Customer
has downloaded and installed the current version of JInitiator but keeps
getting a message to upgrade JInitiator version.
-
Customer has multiple copies of JInitiator installed on the
computer and a previous version is being used as the default version. Customer
needs to remove all previous versions of JInitiator installed on the computer (See
Connecting to Banner 7, number 2).
Back to Top
-
Customer
has the current version of JInitiator installed and cannot get the login
display to access Banner 7.
-
Customer is trying to go to a specific web server. This is being
blocked from outside of the Butrovich building. Customer will need to use the
generic URL for Banner 7.
Banner 7 Production - https://banner.alaska.edu
Banner 7 Training - https://ban7trnx.alaska.edu
Banner 7 PREP - https://ban7prep.alaska.edu
Banner 7 LRGP - https://ban7lrgp.alaska.edu
Back to Top
-
Customer
gets a Microsoft Visual C++ Runtime or Debug error or Oracle Class Foundation
Error Java Class Main Engine Not Found error.
-
Explanation: Customer visited a website that starts up the Java
Runtime Environment (JRE) , such as VistaPlus or NASA's J-Track 3D. When Customer
attempts to access Banner 7, the JInitiator starts up and directly conflicts
with the JRE, causing an error.
-
Solution: If Customer has visited a website that utilizes the
JRE before navigating to Banner 7, then Customer needs to close all Internet
Explorer windows to shutdown the JRE. Open Internet Explorer and navigate
directly to Banner 7.
-
If Customer needs to access VistaPlus along side Banner 7, then
they need to open Banner 7 in Internet Explorer and VistaPlus in an alternate
browser (Mozilla/Firefox, Netscape).
Back to Top
Logging into Banner 7
-
Customer attempts to login to Banner and receives the error message
'ORA-12560: TNS: Protocol Adaptor Error.'
-
It is required to enter the database name when logging
in. In Banner 6, this was not required for PROD and TRNX.
Banner 7 Production - PROD
Banner 7 Training - TRNX
Banner 7 PREP - PREP
Banner 7 LRGP – LRGP
Back to Top
-
Customer
attempts to login to Banner and receives the error message '*ERROR* Invalid
version of GUAINIT.' After Customer clicks OK they receive another error
message 'FRM-40735: ON-ROLLBACK trigger raised unhandled exception ORA-04067.'
-
Customer has attempted to login to a Banner instance that does
not match the URL. For example, Customer used the URL is https://ban7trn7.alaska.edu
but entered PROD for the logon Database. Customer should cancel the login
attempt and return to Banner using the correct URL for the logon Database (See Connecting to Banner 7, number 5).
Back to Top
Navigating/Using Banner 7
-
Drop-down menus
fail to function correctly.
-
Make sure popup blockers are off.
-
If Customer has two monitors, drop-down menus will only work on
the primary monitor.
Back to Top
-
Customer is unable
to see all the contents of the window with the window maximized, requiring
them to scroll up, down, left, and right when using most forms.
-
Monitor resolution settings need to be set at minimum of 1024 x 768.
Back to Top
-
The
F1 key does not work.
-
The F1 key does not work in Banner 7.
For a complete list of toolbar options and keyboard commands see Banner
7 Keystrokes.
Back to Top
-
Customer closed a
grey Internet Explorer window and they were immediately logged out of Banner.
-
The Internet Explorer window, Oracle Application Server Forms
Services, is running a Java Applet that opened the Banner 7 window, Oracle
Developer Forms Runtime - Web. When the Internet Explorer window is closed,
the Java Applet closes, and in the process closes the Banner 7 window.
Back to Top
-
Customer ran an Oracle
Report from GJAPCTL and got a blank screen.
-
Either the report that was just submitted or a previous report
has locked up and the queue is filling up. When the limit has been reached,
the error listed in the next question will appear. This is a known issue with
Oracle and our Technicians are currently working on a monitoring solution.
Back to Top
-
Customer ran an Oracle Report
from GJAPCTL and got an error, "REP-56055: Exceed max connections allowed: 20." or
"REP-56055: Exceed max connections allowed: 40."
-
Of the 32 reports that are run from GJAPCTL, FRR270B and FRR272R
seem to be locking up, causing the queue to backup. This is a known issue with
Oracle and our Technicians are currently working on a monitoring solution.
Back to Top
-
Customer
opens a form in Banner 7 and nothing happens except a blue cursor that moves
back and forth on the lower right corner of the Banner form.
-
SCT is aware of this issue and working on a fix. Our
techs will work on implementing the fix when it is released. The issue effects
users with Query-only access to the following:
| Forms |
Reports |
| SRAQUIK |
SHRDEGS (possibly SHR9EGS) |
| SOILCUR |
SARBDSN |
| SAAQUIK |
|
| SRARECR |
|
| SAADCRV |
|
| SARDCBT |
|
| SAAADMS |
|
| SGASTDN |
|
| SFAREGS |
|
| SHADEGR |
|
Back to Top
-
Customer
using a Mac reports that it is difficult to read the text in Banner 7, and that
some of the text is cut off.
-
There is a known issue with Banner 7 and fonts rendering smaller
on the Mac than on Windows. A couple other schools have noted this issue in
their documentation (UC Santa Cruz, Fashion Institute of Technology) and that
SCT and Oracle are aware of it. SCT talked with the OIT Help Desk and said
that Apple and Oracle have been working together on a version of JInitiator
that would work with Safari, in an effort to resolve a number of issues.
Back to Top
-
Customer is unable to access
the Banner Bookshelf.
-
The Banner Bookshelf is no longer on the toolbar but is a link on
the right side of the main menu.
Back to Top
-
What are 'My
Links'?
-
There are 5 Personal Links available on the Banner main menu.
You can set these to link to whatever you prefer – at your own risk. Problems
with these links are the responsibility of the Customer.
Back to Top
-
What are 'Banner Broadcast
Messages'?
-
The Broadcast feature of Banner 7 will be used to announce Banner
outages.
Back to Top
Last Updated: 10/27/2005
|